When I turned it on I got.
1st LineWhat is wrong with my Raypak Avia (2)ool Set
2nd Line: Alternates between Pre-Purge and Diff Sw Open

At the same time water keeps coming out of the bottom of the exhaust vent. When I increase the pump speed, water comes out faster.

The error log has these notifications for the last few days:
8/17 Critical Fault -Flue Temperature Fault
8/18 Warning Differential Pressure switch failed open during operation. Check blower and Heat exchanger exhaust.
Fan Fault Lockout - Multiple Fan faults detected. Check blower and Air switches.
8/19. Differential Pressure again
8/20 Fan Fault Lockout again.

Any help would be appreciated.

ajw22

TFP Expert

Gold Supporter

Silver Supporter

Bronze Supporter

TFP Guide

Jul 21, 2013
57,479
Northern NJ
Pool Size
35000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
  • Aug 21, 2023
  • Add bookmark
  • #2

Is your heater under warranty?

The Raypak Avia is too new for us to have any experience diagnosing problems here.

It sounds like you have a serious internal water leak in the heater. Have you opened it up and looked at the insides of it?

Your problems sound serious enough to contact a local Avia service center.

1

1poolman1

TFP Expert

In The Industry

Jul 14, 2014
7,802
Sacramento
  • Aug 21, 2023
  • Add bookmark
  • #3

Hudsonbard said:

When I turned it on I got.
1st LineWhat is wrong with my Raypak Avia (4)ool Set
2nd Line: Alternates between Pre-Purge and Diff Sw Open

At the same time water keeps coming out of the bottom of the exhaust vent. When I increase the pump speed, water comes out faster.

The error log has these notifications for the last few days:
8/17 Critical Fault -Flue Temperature Fault
8/18 Warning Differential Pressure switch failed open during operation. Check blower and Heat exchanger exhaust.
Fan Fault Lockout - Multiple Fan faults detected. Check blower and Air switches.
8/19. Differential Pressure again
8/20 Fan Fault Lockout again.

Any help would be appreciated.

Water coming out of the exhaust would indicate a large leak in the heat exchanger. Chemical damage?

Hudsonbard

Member
May 24, 2021
14
Orange County, NY
Pool Size
15000
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-40
  • Aug 21, 2023
  • Add bookmark
  • #5

ajw22 said:

Is your heater under warranty?

The Raypak Avia is too new for us to have any experience diagnosing problems here.

It sounds like you have a serious internal water leak in the heater. Have you opened it up and looked at the insides of it?

Your problems sound serious enough to contact a local Avia service center.

Thanks for your reply.
I can't see enough to find where the water is coming from. I don't want to start taking the machine apart. Every time I touch plumbing, it costs me money.

1

1poolman1

TFP Expert

In The Industry

Jul 14, 2014
7,802
Sacramento
  • Aug 21, 2023
  • Add bookmark
  • #6

Hudsonbard said:

I have SWG and follow TFP chemical guidelines. What chemicals would cause damage?

Usually, if there is heat exchanger damage it is caused by improper water chemistry. Water in the exhaust is usually an indication of that kind of damage. Could have been a mechanical failure. Water in the combustion chamber will cause issues with air flow and the machine will give some of the errors you mention. Just a best guess from 3000 miles away. If it is still under warranty, get it looked at ASAP.

Hudsonbard

Member
May 24, 2021
14
Orange County, NY
Pool Size
15000
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-40
  • Aug 21, 2023
  • Add bookmark
  • #7

Heater was installed on 7/13/23. Does it make sense that there would be chemical damage in that time? In any case, I will pay greater attention to Raypak chemical recommendations in the future.

In case this helpful to others, here was my experience trying to find an Authorized Service Provider.

I live in the Hudson Highlands, 50 miles from NYC and withing the NYC metropolitan statistical area. When I searched for an ASP on the website, it found none within 100 miles. Strange. Checked two towns in wealthy Westchester county, same result. This may have been caused by a browser setting perhaps, but when I searched for our home in Manhattan, it did find some providers.

The service rep at Raypak did a search on the web site and found a bunch of ASR's not ridiculously far away. I could not find the phone number for service on the website. It is 877 271 2592. I had to wait about 20 minutes.

The service Rep said that if none of the ASR's would agree to service the unit, to call Raypak again for an authorized service representative, if I wrote that down correctly, which is not a certified technician, but temporarily permitted to do warranty repair. They get paid $200 for the visit, and if the customer is charged more, we should call Raypak and get the overage reimbursed. And the customer should get any needed part by again calling Raypak, since the servicer would otherwise charge for it.

A plumber is coming tomorrow for something else, and I will ask him to install a bypass for the heater because who knows how long this will take to fix, and my pool is losing water and the interior of the heater is getting wet.

You must log in or register to reply here.

What is wrong with my Raypak Avia (2024)

References

Top Articles
Gober Funeral Chapel – Page 15 – Quad Cities Daily
Gober Funeral Chapel – Page 13 – Quad Cities Daily
Jack Doherty Lpsg
Television Archive News Search Service
Restaurer Triple Vitrage
Costco The Dalles Or
Melfme
The Pope's Exorcist Showtimes Near Cinemark Hollywood Movies 20
How do you mix essential oils with carrier oils?
Call of Duty: NEXT Event Intel, How to Watch, and Tune In Rewards
Midway Antique Mall Consignor Access
Weekly Math Review Q4 3
Signs Of a Troubled TIPM
D10 Wrestling Facebook
The Cure Average Setlist
Char-Em Isd
"Une héroïne" : les funérailles de Rebecca Cheptegei, athlète olympique immolée par son compagnon | TF1 INFO
Chelactiv Max Cream
Why do rebates take so long to process?
Maxpreps Field Hockey
All Obituaries | Gateway-Forest Lawn Funeral Home | Lake City FL funeral home and cremation Lake City FL funeral home and cremation
Jackass Golf Cart Gif
Ultra Ball Pixelmon
Tottenham Blog Aggregator
Current Students - Pace University Online
Korg Forums :: View topic
Pdx Weather Noaa
Willys Pickup For Sale Craigslist
Craigslist Dallastx
JD Power's top airlines in 2024, ranked - The Points Guy
Lehpiht Shop
Scioto Post News
Indiefoxx Deepfake
Mistress Elizabeth Nyc
Natashas Bedroom - Slave Commands
Troy Gamefarm Prices
15 Best Things to Do in Roseville (CA) - The Crazy Tourist
Gun Mayhem Watchdocumentaries
Prior Authorization Requirements for Health Insurance Marketplace
2007 Peterbilt 387 Fuse Box Diagram
Lbl A-Z
Firestone Batteries Prices
Homeloanserv Account Login
Ds Cuts Saugus
Cocorahs South Dakota
Charli D'amelio Bj
Stranahan Theater Dress Code
The Quiet Girl Showtimes Near Landmark Plaza Frontenac
Food and Water Safety During Power Outages and Floods
Minute Clinic Mooresville Nc
Epower Raley's
Heisenberg Breaking Bad Wiki
Latest Posts
Article information

Author: Edwin Metz

Last Updated:

Views: 6261

Rating: 4.8 / 5 (78 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Edwin Metz

Birthday: 1997-04-16

Address: 51593 Leanne Light, Kuphalmouth, DE 50012-5183

Phone: +639107620957

Job: Corporate Banking Technician

Hobby: Reading, scrapbook, role-playing games, Fishing, Fishing, Scuba diving, Beekeeping

Introduction: My name is Edwin Metz, I am a fair, energetic, helpful, brave, outstanding, nice, helpful person who loves writing and wants to share my knowledge and understanding with you.